Shop by Category
- On Sale!
- What's New
- Top Rated
- Best Sellers
- Accessories
- Electronic / Electrical
- GPIB
- Laboratory / Science
- Loggers
- Power
- cPCI / PXI
- Rugged tablet / Handheld
- Soldering/Rework Stations
- Software and Hardware Projects
- PC Systems for Instruments, DAQ, Logging
- PLC and PAC systems for Control
- Calibration and Measurement Systems
Shop by Brand
- Aaeon
- Accel Instruments
- Adlink
- AEMC
- Antaira
- Arbor
- Array
- Asian Electron
- Atek
- Atten
- Best Scope
- Bravo Communications
- Diamond Systems
- Bright Alliance
- Dino-Lite
- Dwyer
- Extech
- Four-Faith
- Frequency Devices Inc.
- GW Instek
- Handywave
- Hioki
- ICS Electronics
- ITECH
- LabJack
- Juniper
- Lascar
- MCC
- Motrona
- MSR
- National Instruments
- Numato
- Omega
- Opto22
- ORing
- PowerVar
- Rigol
- Rugged Tech
- Senonics
- Siglent
- Testo
- Tripp Lite
- TVBTECH
- Twintex
- Vaisala
- Winmate
Rigol DS1102E 100MHz Digital Oscilloscope
$0.00
The Rigol DS1102E oscilloscope is one of the most popular 100 Mhz oscilloscopes if not the most single popular 100 Mhz oscilloscope in the USA in 2013. This unit has countless reviews online and many reviews on this page from our customers. You cant go wrong after reading all the reviews and feedback from customers.
Five years ago a scope like this was unheard pf for sub 1000 dollars prices. Now this unit is 399 with free shipping. The unit also comes with 1 MP of memory. This is huge and extremely useful! The ds 1102e is a website best seller. To get this distiction it has to be one of the most popular scopes we sell.
This Rigol DS1102E Model is an economical digital oscilloscope with high-performance, which is designed with dual channels and 1 external trigger channel. It provides 20 types of wave parameters for automatically measuring, which contains 10 Voltage and 10 Time parameters. In cursor mode, users can easily measure by moving cursor. Besides, 3 types of cursor measurement are optional: Manual, Track and Auto. This DS1102E DSO provides powerful PC application software: UltraScope, which enables to: Capture and measure wave; Perform local or remote operation; Save waves as ".bmp" format; Save files as ".txt" or ".xls" format; Print waveforms.
Easy to Use Design
- Built-in help menu enables information getting more convenient
- Multiple Language User Interface, support Chinese & English input
- Support U disk and local files storage
- Waveform intensity can be adjusted
- To display a signal automatically by AUTO
- Pop-up menu makes it easy to read and use function
- Fine delayed scan function
- Built-in FFT function, hold practical digital filters
- Pass/Fail detection function enables to output testing results
- Math operations available to multiple waves
- Powerful PC application software UltraScope
- Standard configuration interface: USB
- Device, USB Host , RS-232 and support U disk storage and PictBridge print standards
- The new function “Key Lock” can meet the needs of industrial production
- Support for remote command control
Specifications:
Model | DS1102E | DS1052E | DS1102D | DS1052D |
Bandwidth | 50 MHz | 100 MHz | 50 MHz | 50 MHz |
Acquisition | ||||
Sample Modes | Real-Time Sample | Equivalent Sample | ||
Sample Rate | 1GSa/s [1] , 500MSa/s | |||
DS1102X | DS1052X | |||
25GSa/s | 10GSa/s | |||
Inputs | ||||
Input Coupling | DC, AC, GND | |||
Input Impedance | 1MΩ±2%, the input capacity is 18pF±3pF | |||
Probe Attenuation Factors | 1X, 5X, 10X, 50X, 100X, 500X,1000X | |||
Maximum Input Voltage | 400V (DC+AC Peak, 1MΩ input impedance) 40V (DC+AC Peak) [2] |
|||
Time Delay between Channel (typical) | 500ps | |||
Horizontal | ||||
Sample Rate Range | Real-Time: 13.65Sa/s-1GSa/s Equivalent: 13.65Sa/s-25GSa/s |
|||
Waveform Interpolation | Sin(x)/x | |||
Memory Depth | Channel Mode | Sample Rate | Memory Depth (normal) | Memory Depth (long memory) |
Single Channel | 1 GS/s | 16 kpts | N/A | |
Single Channel | 500MS/s Or lower | 16 kpts | 1 Mpts | |
Dual Channel | 500MS/s Or lower | 8 kpts | N.A. | |
Dual Channel | 500MS/s Or lower | 8 kpts | 512 kpts | |
Scanning Speed Range (Sec/div) | 2ns/div~50s/div, DS1102X 5ns/div~50s/div, DS1052X 1-2-5 Sequence |
|||
Sample Rate and Delay Time Accuracy | ±50ppm (any interval ≥1ms) | |||
Delta Time Measurement Accuracy (Full Bandwidth) | Single: ±(1 Sample interval + 50ppm × reading + 0.6 ns) >16 averages: ±(1Sample interval + 50ppm × reading + 0.4 ns) |
|||
Vertical | ||||
A/D Converter | 8-bit resolution, all channels sample simultaneously | |||
Volts/div Range | 2mV/div~10V/div (at the input terminal connecting to BNC) | |||
Maximum Input | Maximum input voltage on analog channel CAT I 300Vrms, 1000Vpk; instantaneous overvoltage 1000Vpk CAT II 100Vrms, 1000Vpk RP2200 10:1:CAT II 300Vrms RP3200 10:1:CAT II 300Vrms RP3300 10:1:CAT II 300Vrms |
|||
Offset Range | ±40V (250mV/div~10V/div) ±2V (2mV/div~245mV/div) |
|||
Analog Bandwidth | 100MHz (DS1102D,DS1102E) 50MHz (DS1052D, DS1052E) |
|||
Single-shot Bandwidth | 100MHz (DS1102D, DS1102E) 50MHz (DS1052D, DS1052E) |
|||
Selectable Analog Bandwidth Limit (typical) | 20MHz | |||
Lower Frequency Response (AC –3dB) | ≤5Hz (at input BNC) | |||
Rise Time at BNC (typical) | <3.5ns, <7ns, respectively at 100MHz, 50MHz | |||
Dynamic range | ±5div | |||
DC Gain Accuracy | 2mV/div-5mV/div: ±4% (In Normal or Average acquisition mode) 10mV/div-10V/div: ±3% (In Normal or Average acquisition mode) |
|||
DC Measurement Accuracy, Average Acquisition Mode | When vertical displacement is zero, and N ≥16: ±(DC Gain Accuracy×reading+0.1div+1mV) When vertical displacement is not zero, and N ≥16: ±[DC Gain Accuracy×(reading+vertical displacement)+(1% of vertical displacement) + 0.2div] When vertical scale is between 2mV/div and 245mV/div, add 2mV more for setting value. When vertical scale is between 250mV/div and 10V/div, add 50mV more for setting value. |
|||
Delta Volts Measurement Accuracy (Average Acquisition Mode) |
Under sam e setting and condition, the voltage difference (?V) between any two points in the waves coming from the average of more than 16 waves have been acquired: ±(DC Gain Accuracy×reading + 0.05 div) | |||
Trigger | ||||
Trigger Sensitivity | 0.1div~1.0div (adjustable) | |||
Trigger Level Range | Internal | ±6 divisions from center of screen | ||
EXT | ±1.2V | |||
Trigger Level Accuracy (typical) applicable for the signal of rising and falling time ≥20ns y | Internal | ±(0.3div × V/div)(±4 divisions from center of screen) | ||
EXT | ±(6% of setting + 200 mV) | |||
Trigger Offset | In Normal mode: pre-trigger (memory depth/ 2*Sample rate), delayed trigger 1s | |||
In Slow Scan mode: pre-trigger 6div, delayed trigger 6div | ||||
Trigger Holdoff Range | 500ns~1.5s | |||
Set Level to 50% (typical) | When input signal frequency ≥50Hz | |||
Edge Trigger | ||||
Edge trigger slope | Rising, Falling, Rising + Falling | |||
Pulse WidthTrigger | ||||
Trigger Condition | (>, <, =) Positive pulse width, (>, <, =) Negative pulse width | |||
Pulse Width Range | 20ns ~10s | |||
Video Trigger | ||||
Video Standard Line Frequency | Support for standard NTSC, PAL and SECAM broadcast systems. Line number range: 1~525 (NTSC) and 1~625 (PAL/SECAM) | |||
Slope Trigger | ||||
Trigger Condition | (>, <, =) Positive slope, (>, <, =) Negative slope | |||
Time Setting | 20ns~10s | |||
Alternate Trigger | ||||
Trigger on CH1 | Edge, Pulse Width, Video, Slope | |||
Trigger on CH2 | Edge, Pulse Width, Video, Slope | |||
Pattern Trigger [2] | ||||
Pattern Type | D0~D15 select H, L, X, , | |||
Duration Trigger [2] | ||||
Pattern Type | D0~D15 select H, L, X | |||
Qualifier | >, <, = | |||
Time Setting | 20ns~10s | |||
Measurements | ||||
Cursor | ||||
Manual | Voltage difference between cursors (∆V) Time difference between cursors (∆T) Reciprocal of ∆T in Hertz (1/∆T) |
|||
Track | Voltage value for Y-axis waveform Time value for X-axis waveform |
|||
Auto | Cursors are visible for Automatic Measurement | |||
Auto Measure | Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay1→2 , Delay1→2 |