GW APS 7050 Programmable linear AC power supply

$0.00

Product Tags:
Product Tags:
GW APS 7050 Programmable linear AC power supply
Features
  • 4.3 inch TFT-LCD Display, Only 88mm(2U) case height
  • Output Capacity: APS-7050(500VA), APS-7100 (1000VA)
  • Arbitrary Waveform FunctionTest Equipment NZgw
  • Surge/ Dip control for output artificial surges or dips in voltage to a DUT
  • Measurement function comprises Voltage, Current, Power, Apparent Power, Current(peak), IPKH, Frequency, Power Factor, Crest Factor
  • 10 sets of the Sequence mode, Simulate mode, and Programming mode
  • 10 sets of Preset allow users to store ten settings
  • Support Sequence, Simulate, and Program to automatically execute output after the equipment power is on
  • Support SCPI Emulation, LabVIEW Driver
  • Standard interface: USB Host, LAN
  • Support remoter control: Sync Output, Program mode signal output, Trigger In/Out, Output on/off
  • Option interface: GPIB (APS-001);RS232/USB CDC (APS-002)

APS-7000 is a series of programmable linear AC power supply, with the height of 2U and output frequency range is 45~500Hz, , the maximum rated output for APS-7050 is 500VA, 310Vrms, 4.2Arms and APS-7100 is 1000VA, 310Vrms, 8.4Arms. The optional collocation can be extended to the maximum output voltage of 600Vrms and maximum output frequency of 999.9Hz. The APS-7000 series comprises nine measurement and test functions (Vrms, Irms, F, Ipk, W, VA, PF, Ipk hold, CF), and provides user interface similar to that of AC Power Meter. The APS-7000 series, via switching many sets of current levels to increase small current measurement resolution, is ideal for the LED industry and standby mode power consumption test. To meet the test criteria of line voltage fluctuation often seen in consumer electronics, APS-7000 series not only supply a stable source of AC, they also features five methods to cope with special purpose or abnormal voltage, frequency, and phase; ten sets of the Simulate mode simulate power outage, voltage increase, and voltage drop; ten sets of the Sequence mode allow users to define parameters and produce sine wave by editing steps; ten sets of the Program mode can edit AC waveform output and define the ceiling and floor level of measurement items for different DUT; Ramp Control allows users to set the variation speed for output voltage rise and fall; Surge/Dip Control simulates DUT’s input power producing a Surge or Dip voltage overlapping with output voltage waveform at a specific time.

The series is ideal for user to produce high complicated waveform and transient waveform to verify electronic product operation under adverse condition.

APS-7000 series currently involves APS-7050 & APS-7100 as below:

 Model name Max. Output Current  Power Rating Output  Voltage 
 APS-7050 4.2A/2.1A  500VA 0~310.0 Vrms 
 APS-7100  8.4A/4.2A 1000VA 0~310.0 Vrms 
APS-7050 Operating Area APS-7100 Operating Area
APS-7050 Output Operating Area  APS-7100 Output Operating Area

Model

APS-7050

APS-7100

Maximum Output Capacity

Power Rating

500VA

1kVA

Output Voltage Setting

 Range

0~155Vrms, 0~310Vrms, 0~600Vrms (APS-003), Auto

Output Maximum Current

 Range

4.2A/2.1A/1.05A (APS-003)

8.4A/4.2A/2.1A (APS-003)

OutputMaximumPeak Current

 Range

16.8A/8.4A/4.2A (APS-003)

33.6A/16.8A/8.4A (APS-003)

Output Frequency Setting

Range

45.0~500Hz

45~999.9Hz(APS-004)

45.0~500Hz

45~999.9Hz(APS-004)

Resolution

0.01Hz(45.0~99.99Hz)
0.1Hz(100.0~500.0Hz)

0.01Hz(45.0~99.99Hz)
0.1Hz(100.0~999.9Hz)

0.01Hz(45.0~99.99Hz)
0.1Hz(100.0~500.0Hz)

0.01Hz(45.0~99.99Hz)
0.1Hz(100.0~999.9Hz)

Setting Accuracy

±(0.02% of setting)

Waveform

Total harmonic distortion

0.5% at 45~500Hz (Resistive load)

Voltage Regulation

Line Regulation

0.1% of full scale

Load Regulation

0.5% of full scale

Measurement

Frequency

Range

45~ 500Hz

Resolution

0.01Hz (45.0~99.99Hz)
0.1Hz (100.0~500.0Hz)

Accuracy

±0.1Hz

With

APS-004

Option

Range

45~ 999.9Hz

Resolution

0.01Hz (45.0~99.99Hz)
0.1Hz (100.0~999.9Hz)

Accuracy

±0.02% of setting

Voltage (r.m.s)

Range

0.2~38.75 Vrms
38.76~77.5 Vrms
77.51~155.0 Vrms
155.1~310.0 Vrms

Resolution

0.01V at 0.00~99.99 Vrms
0.1V at 100.0~310.0 Vrms

Accuracy

±(0.5% of reading+ 2counts)

 With

APS-003

Option

Range

0.2~600Vrms

Resolution

0.01V at 0.00~99.99 Vrms
0.1V at 100.0~600.0 Vrms

Accuracy

±(0.5% of setting+ 2counts)

Current (r.m.s)

Range

2.00~70.00mA
60.0~350.0mA
0.300~
3.500A
3.00~17.50A

Resolution

0.01mA
0.1mA
0.001A
0.01A

Accuracy

±(0.6% of reading+5 counts), 2.00~350.0mA
±(0.5% of reading+5 counts), 0.350~
3.5A
±(0.5% of reading+3 counts), 3.500~17.5A

Power (W)

Resolution

0.01W
0.1W
1W

Accuracy

±(0.6% of reading+5 counts), 0.2~99.99W
±(0.6% of reading+5 counts), 100.0~999.9W
±(0.6% of reading+2 counts), 1000~9999W

Power Factor

Resolution

0.001

Accuracy

±(2% reading+ 2 counts)

Crest Factor

Range

0.00~50.00

Resolution

0.01

General

Remote Output Signal

Pass, Fail, Test-in Process, Trigger in, Trigger out ,Out ON/OFF

Sync Signal Socket

Output Signal 10V, BNC type

Interface

USB Host, LAN
Option
GPIB (APS-001)RS232/USB CDC (APS-002)

Output Mode

Memory

10 (0~9 numeric keys)

AC Input

115/230 Vac±15%

Others

Phase

Single Phase, Two wire (1P2W)

Protection

OCP, OPP, OHP and Alarm

Dimension (W*H*D) & Weight 

430x88x400, 24Kg

430x88x560, 38Kg

 

Sold Out
Product Images (click to enlarge)
  • GW APS 7050 Programmable linear AC power supply
  • GW APS 7050 Programmable linear AC power supply
  • GW APS 7050 Programmable linear AC power supply