Dwyer Series AQTI/AQTIP Air Quality Test Instrument Kits

$0.00

Dwyer Series AQTI/AQTIP Air Quality Test Instrument Kits

AQTI/AQTIP Combines the UHH Universal Handheld with Compatible Probes

THE SERIES AQTI AIR QUALITY TEST INSTRUMENTS combine the versatile Model UHH handheld base with various compatible probes and modules. This versatile combination provides a line of instruments capable of streamlining a technician’s everyday testing by combining all into one product. All compatible probes and modules can be field adapted at any moment and are instantly recognized by any UHH handheld base instrument. The plug and play probes allow a user to run through various tests, eliminating the need to switch instruments and recall how to navigate all the various equipment from multiple vendors, reducing time and simplifying operation. Series AQTI Air Quality Test Instruments come prepackaged in differential pressure, thermo-anemometer, or thermo-hygrometer probe kits. Additional wired and wireless probes may be ordered separately to create any customized test package to suit your needs.

Specifications

UHH SPECIFICATIONS
Languages:
English, German, Italian, Portuguese, Spanish.
Display:
OLED, color 240 x 320.
Temperature Limits:
5 to 125°F (-15 to 51°C);
Note: When using wireless function: 20 to 125°F (-6 to 51°C).
Battery Charging Limits:
32 to 113°F (0 to 45°C).
Resolution:
1 FPM, 0.1 MPS, 0.1 CFM & M3/HR; 0.1°F & °C; RH 0.1%.
Power Requirements:
3 V BR1225 lithium metal battery, installed functional, non-replaceable and 3.7 V YT724368 lithium ion battery, installed functional, non-replaceable.
Maximum Wireless Distance:
50’ (15 m).
Handle Enclosure:
Thermoplastic elastomer over polycarbonate.
Weight:
10 oz (283 g).
Agency Approval:
CE with CE approved charger, RoHS;
Note: Intended to be operated with power cables
less than 3 m in length.

 

AP THERMO-ANEMOMETER PROBE SPECIFICATIONS
Service:
Dry, clean air.
Temperature Limits:
Process: -20 to 212°F (-29 to 100°C); Ambient: 5 to 125°F (-15 to 51°C).
Range:
Air Velocity: 0 to 6000 FPM (0 to 30 m/s);
Volumetric Air: 999,999 in selected flow units;
Temperature: -20 to 212°F (-29 to 100°C).
Accuracy:
Air Velocity: ±3% FS within temperature range of 40 to 90°F (4 to 32°C);
Temperature: ±0.5°F (±0.28°C).
Response Time:
1 s.
Probe Length:
8" (203 mm) insertion.
Weight:
12.8 oz (378.54 g).

 

RP THERMO-HYGROMETER PROBE SPECIFICATIONS
Service:
Clean air.
Temperature Limits:
Process: -40 to 176°F (-40 to 100°C); Ambient: 5 to 125°F (-15 to 51°C).
Range:
RH: 0 to 100% (non-condensing); Temperature: -20 to 140°F (-29 to 60°C).
Accuracy:
RH: ±2% @ 25°C (10 to 90% RH); ±4% (0 to 10, 90 to 100% RH);
Temperature: ±0.54 @ 77°F (±0.3 @ 25°C).
Response Time:
1.5 s.
Probe Length:
8" (203 mm) insertion.
Weight:
12.8 oz (378.54 g).

 

VP VANE THERMO-ANEMOMETER PROBE SPECIFICATIONS
Air Velocity:
Range: 40 to 5000 fpm (0.2 to 25 m/s).
Accuracy: 0.25 to 10 m/s: ±1.5% of reading ±20 fpm (±0.1 m/s); 10 to 20 m/s: 1.5% of reading ±40 fpm (±0.2 m/s); 20 to 25 m/s: ±1.5% of reading ±60 fpm (±0.3 m/s).
Response Time: 1 s.

 

Temperature:
Range: -4 to 140°F (-20 to 60°C).
Accuracy: ±0.54 @ 77°F (±0.3 @ 25°C).
Response Time: 1.5 s.
Relative Humidity:
Range: 0 to 100% RH.
Accuracy: ±2% @ 77°F (25°C) (10 to 90% RH); ±4% (0 to 10% and 90 to 100%).
Response Time: 1.5 s.
Air Volume:
Range: 999,999 in selected units. Response Time: 1 s.
Vane Material:
Anondized aluminum.
Probe Length:
8" (203 mm) insertion.
Weight:
15.2 oz (449.52 g).

 

COMMON PROBE SPECIFICATIONS
Battery Charging Limits:
32 to 113°F (0 to 45°C). (Wireless Only).
Power Requirements:
3.7 V YT562447 Lithium ion battery, installed functional, user replaceable.
(Note: Intended to be operated with power cables less than 3 m in length). (Wireless Only).
Maximum Wireless Distance:
50' (15 m). (Wireless Only).
Handle Enclosure:
Thermoplastic elastomer over polycarbonate.
Supplied With:
Wrist strap.
Agency Approvals:
CE (not while charging), RoHS, FCC compliant.

 

WDPM SPECIFICATIONS
Service:
Non-corrosive dry gases.
Wetted Materials:
Consult factory.
Accuracy:
±0.5% FS span @ 25°C (includes non linearity, hysteresis, and non repeatability).
Pressure Limits:
See Table 1 on WDPM Instruction Manual.
Temperature Limits:
Compensated: 32 to 140°F (0 to 60°C); Process/Ambient: 14 to 140°F (-10 to 60°C).
Thermal Effects:
±0.01% FS/°F (±0.02% FS/°C).
Battery Charging Limits:
32 to 113°F (0 to 45°C).
Power Requirements:
3.7 V YT562447 lithium ion battery, installed functionally, user replaceable.
Wireless Distance:
At least 50' (15 m).
Weight:
2.5 oz (70.87 g).
Connections:
Two barbed connections for use with 1/8" (3.18 mm) or 3/16" (4.76 mm) ID tubing.
Agency Approvals:
CE (not while charging), RoHS, FCC compliant.

Features

  • SERIES AQTI SUPPLIED WITH: UHH, sensing probe with coiled cable, soft carrying case (UHH-C1),
    hand strap (UHH-STRAP), dual USB charger with international power adapters (UHH-ICHRG),
    charger cable (UHH-CBL).
  • SERIES AQTIP SUPPLIED WITH: UHH, wireless sensing probe, soft carrying case (UHH-C1),
    hand strap (UHH-STRAP), dual USB charger with international power adapters (UHH-ICHRG),
    charger cable (UHH-CBL), 2 GB SD card (UHH-SD), heavy duty hard case
    with pre-cut foam inserts for additional sensors (UHH-C2), NIST Calibration Certificate.

Product Literature

Manuals

Model Description
AQTI-AP1 Air Quality Test Instrument with UHH base and AP1 thermo-anemometer probe with coiled cable. Measures air velocity, volumetric flow and temperature.
AQTI-RP1 Air Quality Test Instrument with UHH base and RP1 thermo-hygrometer probe with coiled cable. Measures % RH, temperature, dew point and wet bulb temperature.
AQTI-VP1 Test instrument vane-anemometer relative humidity and temperature wired probe.
AQTI-WDPM-002 Pressure Module Kit, DP manometer, +/- 2" WC, UHH & DP1 hand strap, charger & cable, 2 color 5' tubes, UHH-C1
AQTI-WDPM-005 Pressure Module Kit, DP manometer, +/- 5" WC, UHH & DP1 hand strap, charger & cable, 2 color 5' tubes, UHH-C1
AQTI-WDPM-010 Pressure Module Kit, DP manometer, +/- 10" WC, UHH & DP1 hand strap, charger & cable, 2 color 5' tubes, UHH-C1
AQTI-WDPM-020 Pressure Module Kit, DP manometer, +/- 20" WC, UHH & DP1 hand strap, charger & cable, 2 color 5' tubes, UHH-C1
AQTI-WDPM-030 Pressure Module Kit, DP manometer, +/- 30" WC, UHH & DP1 hand strap, charger & cable, 2 color 5' tubes, UHH-C1
AQTI-WDPM-100 Pressure Module Kit, DP manometer, +/- 100" WC, UHH & DP1 hand strap, charger & cable, 2 color 5' tubes, UHH-C1
AQTI-WDPM-200 Pressure Module Kit, DP manometer, +/- 200" WC, UHH & DP1 hand strap, charger & cable, 2 color 5' tubes, UHH-C1
AQTI-WDPM-350 Pressure Module Kit, DP manometer, +/- 350" WC, UHH & DP1 hand strap, charger & cable, 2 color 5' tubes, UHH-C1
Sold Out
Product Images (click to enlarge)
  • Dwyer Series AQTI/AQTIP Air Quality Test Instrument Kits