Dwyer AQTIA WDPM 350 Air Quality Test Instruments

$0.00

Dwyer AQTIA WDPM 350 Air Quality Test Instruments

Test Instrument, UHH2 and WDPM-002, Wireless +/-350" wc Differential Pressure

AQTIA Combines the UHH2 Universal Handheld with Compatible Probes

Product Applications

  • Building commissioning
  • Building balancing
  • Testing HVAC equipment performance

Specifications

UHH2 SPECIFICATIONS
Display:
4.3" QHD Gorilla glass, 960x540.
Wireless Distance:
50' (15 m) or greater.
Response Time:
1 s.
Temperature Limits:
Operating: -4 to 140°F (-20 to 60°C); Storage: -40 to 176°F (-40 to 80°C).
Humidity Limits:
5 to 95% RH.
Power Requirements:
2000mAh lithium ion battery, installed functional, non-replaceable.
Memory:
RAM 1G & ROM 4G.
Operating System:
Android® 4.2.2.
CPU:
MTK6589W Quad Core 1.2 GHz.
Enclosure Rating:
IP68.
Weight:
15.9 oz (450 g).
Agency Approvals:
CE.

 

AP2 THERMO-ANEMOMETER PROBE SPECIFICATIONS
Service:
Dry, clean air.
Temperature Limits:
Process: -20 to 200°F (-29 to 93°C); Ambient: -20 to 140°F (-29 to 60°C); Battery Charging: 32 to 113°F (0 to 45°C).
Range:
Air Velocity: 0 to 6000 FPM (0 to 30 m/s); Volumetric Air: 999,999 in selected flow units; Temperature: -40 to 212°F (-40 to 100°C).
Accuracy:
Air Velocity: ±3% FS within temperature range of 40 to 90°F (4 to 32°C); Temperature: ±0.5°F (±0.28°C).
Response Time:
1 s.
Probe Length:
8" (203 mm) insertion.
Power Requirements:
3.7 V YT562447 Lithium ion battery, installed functional, user replaceable.
Maximum Wireless Distance:
50' (15 m).
Handle Enclosure:
Thermoplastic elastomer over polycarbonate.
Supplied With:
Wrist strap.
Weight:
11.2 oz (331.22 g).
Agency Approvals:
CE (not while charging), FCC compliant.

 

RP2 THERMO-HYGROMETER PROBE SPECIFICATIONS
Service:
Clean air.
Temperature Limits:
Process: -4 to 140°F (-20 to 60°C); Ambient: 5 to 125°F (-15 to 51°C); Battery Charging: 32 to 113°F (0 to 45°C).
Range:
RH: 0 to 100% (non-condensing); Temperature: -22 to 140°F (-30 to 60°C).
Accuracy:
RH: ±2% @ 25°C (10 to 90% RH); ±4% (0 to 10, 90 to 100% RH); Temperature: ±0.54°F @ 77°F (±0.3°C @ 25°C).
Response Time:
1.5 s.
Probe Length:
8" (203 mm) insertion.
Power Requirements:
3.7 V YT562447 Lithium ion battery, installed functional, user replaceable.
Maximum Wireless Distance:
50' (15 m).
Handle Enclosure:
Thermoplastic elastomer over polycarbonate.
Supplied With:
Wrist strap.
Weight:
11.2 oz (331.22 g).
Agency Approvals:
CE (not while charging), RoHS, FCC compliant.

 

VP2 VANE THERMO-ANEMOMETER PROBE SPECIFICATIONS
Service:
Clean air.
Temperature Limits:
Process: -4 to 140°F (-20 to 60°C); Ambient: 5 to 125°F (-15 to 51°C).
Range:
Air Velocity: 50 to 5000 fpm (0.25 to 25 m/s); Temperature: -22 to 140°F (-30 to 60°C); Relative Humidity: 0 to 100% RH; Air Volume: 999,999 in selected units.
Accuracy:
Air Velocity: 0.25 to 10 m/s: ±1.5% of reading ±20 fpm (±0.1 m/s); 10 to 20 m/s: 1.5% of reading ±40 fpm (±0.2 m/s); 20 to 25 m/s: ±1.5% of reading ±60 fpm (±0.3 m/s); Temperature: ±0.54°F @ 77°F (±0.3°C @ 25°C); Relative Humidity: ±2% @ 77°F (25°C) (10 to 90% RH); ±4% (0 to 10% and 90 to 100%).
Response Time:
Air Velocity: 1 s; Temperature: 1.5 s; Relative Humidity: 1.5 s; Air Volume: 1 s.
Probe Length:
8" (203 mm) insertion.
Power Requirements:
3.7 V YT562447 Lithium ion battery, installed functional, user replaceable.
Battery Charging Limits:
32 to 113°F (0 to 45°C).
Maximum Wireless Distance:
50' (15 m).
Vane Material:
Anondized aluminum.
Handle Enclosure:
Thermoplastic elastomer over polycarbonate.
Supplied With:
Wrist strap.
Weight:
13.6 oz (402.20 g).
Agency Approvals:
CE (not while charging), RoHS, FCC compliant.

 

WDPM SPECIFICATIONS
Service:
Non-corrosive dry gases.
Wetted Materials:
Consult factory.
Accuracy:
±0.5% FS span @ 25°C (includes non linearity, hysteresis, and non repeatability).
Pressure Limits:
See model chart on catalog page.
Engineering Units:
Pressure: in w.c., ft w.c., in Hg, psi, OzSl, mm w.c., cm w.c., mBar, Pa, hPa, and kPa; Velocity: fpm, mph, kn, m/s, m/h, k/h, and fps; Flow: cfm, gpm, gph, gpd, m3/s, m3/h, lps, lpm, and lph.
Temperature Limits:
Compensated: 32 to 140°F (0 to 60°C); Process/Ambient: 14 to 140°F (-10 to 60°C).
Thermal Effects:
±0.01% FS/°F (±0.02% FS/°C).
Battery Charging Limits:
32 to 113°F (0 to 45°C).
Power Requirements:
3.7 V YT562447 lithium ion battery, installed functionally, user replaceable.
Wireless Distance:
At least 50' (15 m).
Connections:
Two barbed connections for use with 1/8" (3.18 mm) or 3/16" (4.76 mm) ID tubing.
Weight:
2.5 oz (70.87 g).
Agency Approvals:
CE with CE approved charger, RoHS, FCC.

Product Literature

Manuals

Sold Out
Product Images (click to enlarge)
  • Dwyer AQTIA WDPM 350 Air Quality Test Instruments
  • Dwyer AQTIA WDPM 350 Air Quality Test Instruments